ENT RF Plasma Surgical System
The ENT RF Plasma Surgical System is designed for otolaryngology procedures requiring controlled soft tissue ablation and coagulation. The system can be configured with an RF generator, compatible surgical probes, a footswitch, and other accessories according to the selected model.
Core functions: RF energy delivery for tissue ablation and coagulation, subject to the device's validated operating modes.
System configuration: Generator, compatible probes, control accessories, and optional components according to the selected configuration.
For B2B buyers: Product specifications, accessory compatibility, intended use, and regulatory documentation can be reviewed during product evaluation.
-
Thyroid Nodule Ablation NeedleErgonomic design for accurate, fatigue-free operationview more
Flexible stopper + ultrasound imaging marks for pinpoint positioning
Low plasma frequency reduces radiation damage... -
Tonsillectomy Plasma Electrodes - Traditional Three WiresControlled working temperature of 40-70 degreesview more
Minimally-invasive plasma ablation and coagulation functions
Bipolar coagulation for achieving efficient hemostasis -
Tonsillectomy Plasma Electrodes -Upgrade Double UCarefully Curated & Tested Materialsview more
Repeatedly Validated Manufacturing Processes
Complete Elimination of Collateral Thermal Damage
Precise Energy Regulation -
Tonsillectomy Plasma ElectrodesCarefully Selected and Tested Materialsview more
Repeatedly Verified Manufacturing Technique
Thoroughly eliminated Collateral Thermal Damage -
Soft Palate Reduction Plasma ElectrodesRetractable saline delivery sheath Easy adjustment between cut and controlled ablation-channeling sheath positions.Eliminates need for saline gel typically used with other Plasma Surgical...view more
-
RF Plasma Surgical Electrodes - Bipolar ForcepsParotid Gland Tumor Resectionview more
Submandibular Gland Tumor Resection
Pyriform Sinus Fistula Repair -
Laryngeal Tumor RF Plasma Surgical ElectrodesIndicated for irrigation, suction, cutting, ablation, coagulation, and hemostasis in laryngeal surgery. It is particularly useful for treating minor laryngeal pathologies in pediatric patients...view more
-
Bleeding Control Plasma Electrodes for Nasal EpistaxisIndicated for simple nosebleed, assisted hemostasis in nasal cavity and sinus surgery. Can penetrate into the narrow temporal part of the nasal cavity.view more
-
Turbinate Reduction RF Plasma Surgical ElectrodesThe fine shaft design of 1.6mm diameter achieves minimally invasive and precise ablation, and minimal incision.view more
The shaft design with markers provides surgeons with scale guide to achieve... -
OTO'VIEW Otological RF Plasma Surgical ElectrodesIt meets the clinical needs for comprehensive application of energy and instruments in the otoscopic surgeries.view more
↵

The system is intended for the specific otolaryngology procedures covered by its applicable product labeling and Instructions for Use (IFU).
Nasal procedures: Potential applications include inferior turbinate reduction and other indicated nasal soft tissue procedures.
Pharyngeal procedures: Potential applications include tonsil and other pharyngeal soft tissue procedures, subject to the approved intended use.
Laryngeal procedures: Application suitability depends on the device model, compatible probe, and applicable clinical indications.
Application confirmation: Buyers should identify their intended procedures and target markets when requesting product documentation.
System configuration and compatible accessories
RF generator
Provides the available output modes and power settings for the selected model.
Surgical probes
Probe types, shaft lengths, tip designs, and single-use or reusable status depend on the available product range.
Footswitch and handpiece
Available control accessories and handpiece configurations should be specified in the quotation.
Compatibility
Generator and probe compatibility must be confirmed against the manufacturer's approved compatibility list.
Technical specifications
|
Parameter |
Specification |
|
Product type |
ENT RF Plasma Surgical System |
|
Technology |
Bipolar radiofrequency plasma |
|
Operating temperature |
40°C–70°C |
|
Input voltage |
AC 100–240 V |
|
Input frequency |
50/60 Hz |
|
Maximum ablation power |
200 W |
|
Maximum coagulation power |
80 W |
|
Operating frequency |
100 kHz ± 10 kHz |
|
Ablation settings |
Levels 1–9 |
|
Coagulation settings |
Levels 1–5 |
|
Saline irrigation rate |
30–120 mL/min |
|
Generator dimensions |
380 × 320 × 140 mm |
|
Generator weight |
6.5 kg |
|
Footswitch |
Dual-pedal configuration |
|
Compatible accessories |
Compatible ENT RF plasma probes and accessories |
|
Probe specifications |
Model-dependent |
The specifications above are based on the preliminary product information provided. Final values and applicable configurations should be verified against the technical documentation for the actual model offered.
Quality control and regulatory documentation
Quality management: Manufacturing quality controls and applicable quality system certifications should be documented for the relevant manufacturing site.
Product testing: Applicable electrical safety, electromagnetic compatibility, and other verification records may be provided according to product status and disclosure requirements.
Traceability: Batch or serial number traceability should be described according to the manufacturer's actual procedures.
Regulatory documentation: Available documents may include product labeling, IFU, declarations of conformity, certificates, and market-specific regulatory records, where applicable.
All certification and regulatory statements must correspond to the actual product model, legal manufacturer, and target market.
OEM/ODM and customization
OEM/ODM services are subject to the manufacturer's validated capabilities, regulatory requirements, and project scope.
Private-label options: Branding, product labeling, and packaging customization, where available.
Configuration support: Evaluation of generator and probe configurations according to the intended application and approved product design.
Product development: Custom engineering or accessory development may be considered following technical feasibility assessment and agreement on validation and regulatory responsibilities.
Project evaluation: Buyers should provide their target market, required configuration, estimated order quantity, and documentation needs.
Supply and after-sales support
Bulk supply
Order quantities, production capacity, and lead times should be confirmed for the requested configuration.
Consumables and spare parts
Availability, ordering requirements, and continued supply arrangements should be confirmed before purchase.
Technical support
Training materials, troubleshooting guidance, maintenance services, and warranty terms depend on the manufacturer's actual support policy.
Shipping and documentation
Packaging, shipping terms, and export documents can be specified according to the destination market and order requirements.
Frequently asked questions

Request a quote and technical documentation
Contact us to discuss product specifications, available configurations, regulatory documentation, bulk supply, or OEM/ODM cooperation.
To help us prepare a relevant quotation, please provide:
Product requirements: Intended procedures, preferred model, and required accessories.
Target market: Destination country or region and applicable regulatory requirements.
Order quantity: Estimated initial order and annual purchasing volume, if available.
Customization requirements: Branding, labeling, packaging, or other requested modifications.
Documentation needs: Required technical files, IFU, certificates, and other applicable product records.
As one of the most professional ent rf plasma surgical systems manufacturers and suppliers in China, we're featured by quality products and good price. Please rest assured to buy bulk ent rf plasma surgical systems for sale here from our factory. Customized orders are welcome.
Ear Dissector, OTO VIEW Otological RF Plasma Surgical Electrodes, Plasma Surgery Disposables